All In Biotech

Free tool

FAERS Monitor: Fentanyl Citrate

The FDA Adverse Event Reporting System collects reports from patients, clinicians and manufacturers. Counts are unverified reports, not rates: they rise with how widely a drug is used, how long it has been sold and media attention, a report can name several drugs, and a report does not show the drug caused the event.

Last checked: Nov 20, 2026FDA FAERS (openFDA) last updated: Oct 28, 2026Methods & limitations

Reports naming NDA 019115 or its brand name (Fentanyl Citrate, Fentanyl Citrate). Reports on generic versions are filed under their own applications.

Reports

17,840

Serious

15,772

88% of reports

Hospitalization

3,551

Death reported

6,175

Any cause; not necessarily from the drug

Most reported reactions

MedDRA preferred terms.

  • dependence3,935
  • overdose2,456
  • death2,065
  • drug abuse1,737
  • toxicity to various agents1,385
  • ill-defined disorder1,288
  • cardiac arrest918
  • respiratory arrest737
  • drug ineffective715
  • drug hypersensitivity628
  • nausea607
  • pain574
  • wrong technique in drug usage process488
  • off label use458
  • accidental overdose457

Reports by year received

View as table
YearReports
200472
2005115
2006235
2007154
2008261
2009272
20101,148
2011563
2012696
2013404
2014429
2015510
2016595
20171,230
20181,319
20191,207
20201,031
2021760
2022834
20234,700
2024599
2025432
2026272

Disproportionality screen

Proportional reporting ratio (PRR): how much more often each reaction appears in this drug's reports than in the other 21,036,319 FAERS reports. Flagged when PRR is at least 2, chi-squared at least 4 and there are 3 or more reports (Evans criteria). A screening statistic only.

ReactionReportsPRR95% CI lowerChi-squared
dependenceSignal3,93591.188.5326,235
respiratory arrestSignal73732.430.121,809
ill-defined disorderSignal1,28825.524.229,757
drug abuseSignal1,73725.124.039,496
wrong technique in drug usage processSignal48816.014.76,784
accidental overdoseSignal45714.913.65,850
overdoseSignal2,45613.613.128,543
cardiac arrestSignal91813.212.410,305
toxicity to various agentsSignal1,3859.89.310,871
drug hypersensitivitySignal6283.83.61,321
deathSignal2,0652.82.72,541
pain5741.11.05
nausea6070.90.86
drug ineffective7150.60.6155
off label use4580.60.6114

A high PRR for a reaction that is also the condition being treated (for example "disease progression" for a cancer drug) is expected and is not a safety signal.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.