Chlorhexidine-Alcohol Versus Povidone Iodine-Alcohol, Combined or Not With Use of a Bundle of New Devices, for Prevention of Intravascular-catheter Colonization and Catheter Failure

Skin Antisepsis With Chlorhexidine-Alcohol Versus Povidone Iodine-Alcohol, Combined or Not With Use of a Bundle of New Devices, for Prevention of Intravascular-catheter Colonization and Catheter Failure: An Open Label, Single Center, Randomized Controlled, Two-by-two Factorial Trial

Last checked: Nov 19, 2026Latest source record: Oct 31, 2019 (this record)Source: ClinicalTrials.govMethods & limitations

CompletedPivotal-lookingRandomized with 1,000 participants. This is a heuristic, not a regulatory label.

Status

Completed

Enrollment

1,000

Actual

Start

Jan 7, 2019

Primary completion

Sep 27, 2019

Study completion Sep 27, 2019

Sponsor

Lead sponsor
Poitiers University HospitalAcademic, hospital or other
Sponsor type
Academic, hospital or other
First posted
Nov 28, 2018

More drug trials from this sponsor

Design

Study type
Interventional
Phase
Phase 4
Allocation
Randomized
Model
Parallel
Masking
None
Primary purpose
Prevention
FDA-regulated drug
No
Who can join
All sexes, from 18 years
Healthy volunteers
No

Summary

As written by the sponsor on the registry.

Short peripheral intravenous catheters (PVC) are the most frequently used invasive medical devices in hospitals. Unfortunately, PVCs often fail before the end of treatment due to the occurrence of complications, which can be mechanical, vascular or infectious. Complications lead to infusion failure and device replacement, which results in interrupted therapy, pain associated with resiting and increased health care costs for resources and staff time. Catheter related bloodstream infections (CR-BSIs) prolong hospitalization and increase treatment costs and mortality. Prevention of these complications is based on the respect of hygiene rules and the use of bio-compatible catheters. The choice of the antiseptic solution for skin disinfection is key. Similarly, the use of new technologies such as catheters designed to minimize blood exposure, zero-reflux needleless-connectors, disinfecting caps, and flushing PVCs before and after each medication administration to maintain catheter patency are of theoretical interest, but little scientific data support their use in routine. The primary objectives of this study are, first, to demonstrate that skin preparation with 2% chlorhexidine (CHG)-70% isopropanol decreases the risk of PVC colonization compared to skin preparation with 5% povidone iodine (PVI)-69% ethanol. Second, to demonstrate that use of a bundle of technologies including a new PVC, zero-reflux needless-connectors, disinfecting caps, and single-use prefilled flush syringes extends the time between catheter insertion and catheter failure. The secondary objectives are to compare between the four study group incidence of phlebitis, accidental catheter removal, infiltration, catheter occlusion, CR-BSI, local infection, all-cause bloodstream infections, catheter colonization, duration of catheter remaining in place without complication, length of hospital stay, safety and patient satisfaction. The CLEAN 3 study is an open-label, single centre, investigator-initiated, randomised, four-parallel group, two-by-two factorial trial. Patients requiring PVC for an expected 48 h will be randomised in one of four groups according to skin disinfection method and type of devices used. Randomization will be carried out through a secure web-based randomization system. Inclusions are expected to begin in January 2019 and continue until July 2019, once the number of catheters required has been reached. Patients will be enrolled at the Emergency department of the Poitiers University Hospital before being hospitalised in one of five wards (neurology, neurology, pneumology, internal medicine and downstream emergency unit).

Conditions

  • Intravascular-catheter Colonization
  • Catheter Failure

Interventions

  • Povidone-Iodine-AlcoholDrug

    Povidone-Iodine-Alcohol will be used to disinfect the skin

  • Chlorhexidine-AlcoholDrug

    Chlorhexidine-Alcohol will be used to disinfect the skin

  • Insyte Autoguard BC WingedDevice

    Pose of Insyte Autoguard BC Winged

  • Nexiva single port catheter, MaxZero needless connector, PureHub Deinfecting Caps and Posiflush prefilled saline syringesDevice

    Pose of Nexiva single port catheter

Primary outcomes

What the sponsor says the trial is designed to measure.

  1. Incidence of catheter-related infectious complicationsTime frame: 8 days
  2. Time between catheter insertion and catheter failureTime frame: 8 days

Locations

1 site in 1 country. Site status is shown where the registry gives one.

  • University Hospital of Poitiers

    Poitiers, France

Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.

For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.