Drug Trial Radar · NCT06965790
Study on Sex-specific, Individualized Dose Calculation of Contrast Agent in CT Examinations
Last checked: Nov 19, 2026Latest source record: Dec 9, 2025 (this record)Source: ClinicalTrials.govMethods & limitations
Status
Recruiting
Enrollment
400
Planned (sponsor's estimate)
Start
Apr 1, 2025
Primary completion
Mar 2026
Study completion Mar 2027
Sponsor
- Lead sponsor
- University Hospital AugsburgAcademic, hospital or other
- Sponsor type
- Academic, hospital or other
- First posted
- May 11, 2025
Design
- Study type
- Interventional
- Phase
- Not applicable
- Allocation
- Randomized
- Model
- Parallel
- Masking
- Single (outcomes assessor)
- Primary purpose
- Other
- FDA-regulated drug
- No
- Who can join
- All sexes, from 18 years
- Healthy volunteers
- No
Summary
As written by the sponsor on the registry.
A large proportion of radiological CT examinations require the intravenous administration of iodine-containing X-ray contrast medium. According to current guidelines, the amount required for CT examinations in the (portal) venous phase is calculated on the basis of body weight (e.g. 0.2-0.4 g iodine/kg body weight), but a standardized application dose of the contrast agent is often also used. In earlier studies, the investigators found that the iodine contrast in vessels and organs achieved with a standardized amount of contrast agent differs significantly between women and men. On average, women showed around 10% higher iodine contrast than men of the same height and weight. The investigators attribute these differences to physiological, sex-specific differences in blood volume. For example, the blood volume of a woman 175 cm tall and weighing 75 kg is approx. 400 ml less than that of a man of the same height and weight (approx. 4.6 vs. 5.0 l, calculated according to Nadler). Taking blood volume into account, sex was no longer a significant influencing factor in a retrospective cohort (n=274). The investigators would now like to investigate these results in a prospective study. For this purpose, two groups of patients with a clinical indication for a contrast-enhanced CT scan in the venous phase will be compared: 1. control group with regular weight-adjusted (n = 200) 2. study group with dosing according to blood volume (n = 200). The hypothesis is that the application scheme adapted to the blood volume leads to a more homogeneous contrasting of women and men. In order to quantify this effect, the iodine contrast values of both groups will be quantitatively analyzed, taking into account other influencing variables (height, weight). The investigators hope that this approach will reduce or even eliminate the observed sex-specific differences. This would lead to a sex-equal contrast based on an individualized amount of contrast medium.
Conditions
- CT Scans
- Contrast Media
- Gender
- Womens Health
Interventions
contrast media (Imeron 350, active ingredient Iomeprol) volume according to sex-specific blood volumeDrug
Calculation of the standardized contrast agent (Imeron 350, active ingredient Iomeprol) quantity (0.35 g iodine/kg) and calculation of the specific blood volume using the established Nadler formula for male and female. Adjustment of the contrast agent according to the ratio of the blood volumes. The amount of saved contrast agent is replaced 1:1 by NaCl.
Primary outcomes
What the sponsor says the trial is designed to measure.
- Sex-specific contrast difference in the vessels and organsTime frame: 1 year
- Contrasting the organs after adjusting the application dose of the contrast agent to the specific blood volumeTime frame: 1 year
Locations
1 site in 1 country. Site status is shown where the registry gives one.
University Hosptial Augsburg
Augsburg, Bavaria, Germany · Recruiting
Contact details for sites and study staff are not shown here. To ask about taking part, use the contact information on the registry record.
For information only. Nothing on this page is investment, legal, tax or medical advice, and nothing here is an offer to sell or a solicitation of an offer to buy any security. The data comes from public government sources, which can be incomplete, delayed or wrong. Check the original record before relying on it.